NOTE: In order to change
the combinations,
obtain the control key and chart showing combinations possible for each lock.
![]() |
Insert control key and turn it right one-quarter turn to position as shown above. Open door. |
![]() |
Revolve dial to the right at least one complete turn, stopping at zero (0). |
![]() |
Depress push-button on back of lock case and hold in depressed position. |
![]() |
With other hand, turn dial right to number 48. Do not turn dial more than two numbers with button depressed. Then release push-button. |
![]() |
Turn dial to the right until you hear click. Then stop. The combination has now been changed. |
![]() |
Close locker door. Remove key by turning it one quarter turn to left, back to original position. |
| 7 | Combination has now been changed automatically to next combination assigned. Dial the new combination (see chart for dialing numbers) to be certain that combination has been properly changed. |
| 8 | If a mistake was made in following above instructions, dial first combination (see chart). If it does not work, dial next combination, etc., until correct combination to open lock is reached |
|
9 |
IMPORTANT. Make sure combination change is reported to lock supervisor so records can be brought up to date. |
TO INSTALLER: Locking nuts are packed separately in a plastic bag containing sufficient nuts for all locks in each shipping case. After locker numbers have been written on combination tags, deliver tags to office of locker administrator so master chart can be completed.
NOTE: Master keys and charts have been sent separately by UPS registered mail.
Required Door Thickness: .030" - .12511 all products except 1670/1671 .04511 - .12511